Naslov OPTIMIRANJE POLOŽAJA MINI-DENTALNIH IMPLANTATA OBZIROM NA SAVIJANJE
Naslov (engleski) POSITION OPTIMISATION OF THE MINI-DENTAL IMPLANTS DUE TO BENDING
Autor Marin Krisla
Mentor Dražan Kozak (mentor)
Član povjerenstva Dražan Kozak (član povjerenstva)
Član povjerenstva Željko Ivandić (predsjednik povjerenstva)
Član povjerenstva Pejo Konjatić (član povjerenstva)
Ustanova koja je dodijelila akademski / stručni stupanj Sveučilište Josipa Jurja Strossmayera u Osijeku Strojarski fakultet u Slavonskom Brodu Slavonski Brod
Datum i država obrane 2016-09-22, Hrvatska
Znanstveno / umjetničko područje, polje i grana TEHNIČKE ZNANOSTI Strojarstvo
Sažetak U radu je bilo potrebno analizirati utjecaj položaja mini - dentalnih implantata na naprezanje na savijanje u bezubim čeljustima. Bezubost, djelomična ili potpuna je i u današnje vrijeme, kada su dostupna mnoga znanja i tehnike prevencije, još uvijek izrazito prisutna u svijetu. Bezubost je problem na koji se mora intervenirati, zato što pacijent zbog narušavanju funkcije i estetike može razviti psihosocijalne probleme, a svaki od njih ima probleme sa funkcijama stomatogantnog sustava.
Kao rješenje bezubosti najviše se ističu mobilne proteze na tri ili četiri oseointegrirajuća imaplantata. Implantati se u današnje vrijeme najčešće izrađuju od titana i njegovih legura zato što je to materijal koji je biofunkcionalan, biokompatibilan i nije podložan biodegradaciji. Vrlo važno je poznavati mehanička svojstva materijala koji se koristi kao nadomjestak kako nebi došlo do odbacivanja ili loma implantata, a samim time i nezadovoljstva pacijenta.
Modeliranje bezubih čeljusti kao i pravilno zadavanje mehaničkih svojstava kosti isto je tako zahtjevan posao iz razloga što je mehanički gledano kost kompozitni materijal s više različitih čvrstih i tekućih faza. Na taj je način struktura koštanog tkiva kompleksna, višefazna, heterogena i anizotropna. U rješenju ovih problema uvelike je pomogao softver Simpleware.
Jednom od numeričkih metoda bilo je potrebno odrediti ekvivalentna naprezanja u kosti u okolini implantata. Izabrana je metoda konačnih elemenata (MKE), a softver za analizu Ansys Workbench.
Naprezanja u kosti u okolini navoja implantata ne prelaze 10 MPa. Najveća naprezanja u kosti (40-50 MPa) pojavljuju se u okolini vrata implantata, zbog okluzalne sile koja savija implantat i tako dodatno opterećuje kost. Rezultati naprezanja su zadovoljavajući. Analizom naprezanja za implantate kojima je promijenjena pozicija zaključeno je da su naprezanja približno jednaka, što znači da samo pozicioniranje implantata i njihov položaj u kosti ne igra značajnu ulogu. Primjenom i analizom naprezanja za mini - dentalne implantate većeg promjera zaključeno je kako je naprezanje u okolnoj kosti smanjeno, kako u okolini navoja implantata, tako i u okolini vrata implantata.
Sažetak (engleski) In this thesis there was an analysis of the impact of positioning the mini - dental implants on the bending stress in edentulous jaws. Edentulism, partial or complete, is even today, with all the knowledge and numerous techniques of prevention existing, still very present in the world. Edentulism is a problem that needs an intervention because a patient due to disruption of function and aesthetics may develop psychosocial problems, and each of them has problems with functions of stomatognathic system.
As a solution to edentulism those that stand out the most are removable dentures for three or four osseous implants. The implants are at present most commonly made of titanium and its alloys because it is the type of material which is bio functional, biocompatible and it is not subject to biodegradation. It is very important to know the mechanical properties of the material used as a substitute so as to prevent rejection or fracture of the implant, and thus even greater patient dissatisfaction.
Modeling toothless jaws and properly placing the mechanical properties of bone is also a demanding job because from the mechanical point of view a bone is a composite material with different solid and liquid phases. Thus the structure of the bone tissue is complex, multiphase, heterogeneous and anisotropic. In the solution of these problems Simpleware software was of great help.
Using one of the numerical methods, it was necessary to determine the equivalent stress in the bone surrounding the implant. Finite element method (FEM) and analysis software Ansys Workbench were chosen for this task.
Stresses in the bone around the implant threads do not exceed 10 MPa. The maximum stress in the bone (40-50 MPa) appear around the neck of the implant, due to occlusal forces that bend the implant and thus put additional strain on the bone. The results of stress are satisfactory. The stress analysis of the implant with a changed position, it was concluded that the stress was approximately equal, which means that only the positioning of implants and their position in the bone does not play a significant role. Applying the stress analysis for the mini - dental implants larger in diameter, it was concluded that the stress in the surrounding bone was reduced, around threaded implants, as well as around the implant neck.
Ključne riječi
bezubost
mandibula
maxilla
mini - dentalni implantat
naprezanje na savijanje
Ključne riječi (engleski)
edentulous jaws
mandible
maxilla
mini - dental implant
bending stress
Jezik hrvatski
URN:NBN urn:nbn:hr:153:405639
Studijski program Naziv: Strojarstvo; smjerovi: Konstruiranje i razvoj proizvoda, Logistika proizvodnje, Inženjerstvo materijala, Strojarske tehnologije, Energetska postrojenja Smjer: Konstruiranje i razvoj proizvoda Vrsta studija: sveučilišni Stupanj studija: diplomski Akademski / stručni naziv: magistar/magistra inženjer/inženjerka strojarstva (mag.ing.mech.)
Vrsta resursa Tekst
Način izrade datoteke Izvorno digitalna
Prava pristupa Pristup korisnicima matične ustanove
Uvjeti korištenja
Datum i vrijeme pohrane 2016-09-27 08:03:42